These instructions apply to the following model:
MASTER-B AND SLAVE-B CONTROL BOARDS FOR DOMO SWING AUTOMATED SYSTEMS
The DOMO automated system consists of non-reversing electro-mechanical linear operators, powered by a 12 Vdc work battery,
each coupled to a control board recharging the battery.
The SLAVE-B equipment (required on 2-leaf gates only) is controlled by the MASTER-B equipment to which all accessories and
pulse generators are connected. The MASTER-B board can be programmed and is used to set the following: function logics, work
times (by self-learning) and pause times, leaf speed, and the sensitivity of the anti-crushing device.
The non-reversing system guarantees the gate will automatically lock when the motor is not operating. A release system enables
the gate to be moved by hand in case of malfunction.
The DOMOSWING automated system was designed and built for controlling vehicle access. Do not use for any other purpose.
1.

DESCRIPTION AND TECHNICAL SPECIFICATIONS

b
Control board
c
Board support
d
Work battery
e
Terminal board (MASTER-B only)
f
Transformer (Optional)
Enclosure in class IP 55
3.
MASTER-B CARD TECHNICAL SPECIFICATIONS
Power supply
Transformer characteristics
Accessories max. load at 24 Vdc
Rapid connector max load
Function logics
Automatic / "Stepped" Automatic /
Safety device / "Stepped" semi-automatic
Opening/closing time
Pause time
Leaf delay time when opening and closing
(op 0s, cl 0s) - (op 2s, cl 2s) - (op 2s, cl 4s) - (op 2s, cl 8s)
Speed
Static force adjustment
Terminal board inputs
Stop - Safety devices at opng. - Safety devices at clsng.
Terminal board outputs
Rapid connector
Programmable functions Logic - pause time - leaf opening
and closing delay - anti-crushing force - operators speed
MASTER-B AND SLAVE -B CONTROL BOARDS
12Vac
Primary 230 Vac~50/60Hz -
Secondary 12 Vac - 16VA
150 mA
50 mA
By self-learning
Programmable: 5, 10, 20, 30 sec.
Selectable on 4 levels
Selectable on 4 levels
Open - Open released leaf
Flashing lamp - Motor - Bus -
indicator-light - Accessories
24 Vdc - 12 Vdc power supply
Minidec cards - RP cards
2.
DIMENSIONS
• Dimensions in mm
Fig. 1
4.
SLAVE-B CARD TECHNICAL SPECIFICATIONS
Power supply
Terminal board outputs
Terminal board inputs
5.
MASTER-B AND SLAVE-B CARDS COMMON
CHARACTERISTICS
Batteries
hermetic Pb 12Vdc 1.2Ah - dimensions 96x46x50
Use frequency (cycles/hour)
Consecutive cycles
Battery recharge time
Enclosure protection class
Motor max current
Operating ambient temperature
Protection fuses
Anti-crushing function
(1)
The 5 cycles/hour are just a reference value for maintaining full
efficiency of batteries. 15 consecutive cycles can be averagely
performed with charged battery. The recovery time (battery recharge)
is approx. 10' each cycle performed. The consecutive cycles could be
reduced by over 50% at low temperatures (< 0°C).
17
CONTROL BOARD
ENCLOSURE
Fig. 2
from Master-B
Motor
Battery - Bus
5
(1)
~15
(1)
~10' for each completed cycle (1)
IP 55
15A
-20°C ÷ +55°C
N° 1 - 20A
Encoder - Current control