sACN – The fixture uses the DMX control data received via sACN at its Ethernet port.
•
It is necessary to set up an Ethernet network. To configure the fixture to receive
control data via sACN, you may need to set an IP Address, IP Subnet and sACN
universe (see Ethernet Config below).
Ethernet config
Lets you set up an IP Network if controlling the fixture by Art-Net or sACN.
Addressing mode
Lets you choose how the fixture acquires its IP Address:
Auto 2.x.x.x. – the fixture will generate its own IP address within the range 2.x.x.x (Art-
•
Net specification)
Auto 10.x.x.x. – the fixture will generate its own IP address within the range 10.x.x.x
•
(Art-Net specification)
DHCP – the fixture will acquire its IP address automatically by DHCP
•
Custom IP – you can assign IP addresses manually by entering individual IP
•
addresses and Subnet mask (see Custom IP Address and Custom IP Subnet below)
- Custom IP Address – lets you set a custom IP Address.
- Custom IP Subnet – lets you set a custom IP Subnet mask.
ArtNet Port
Selects an Art-Net port/universe from 00000 (Network 0 / Subnet 0 / Universe 0) to 32767
(Network 7 / Subnet 15 / Universe 255).
Note that the first Art-Net universe is considered to be universe number 00000, not
00001.
sACN Universe
Selects a sACN universe from 00001 to 63999.
Fixture Settings
Tilt Invert
Inverts direction of Tilt:
OFF (the default setting) – Normal Tilt control: positive Tilt values turn the head
•
towards the front of the fixture
ON – Inverted Tilt control: positive Tilt values turn the head towards the back of the
•
fixture
Position feedback
Enables/disables head position feedback (auto Tilt correction):
Position Feedback is enabled by default.
•
If you disable Position Feedback, the fixture will not automatically correct any errors
•
in Tilt position. In this case, if the head loses its correct Tilt position you must carry out
a reset to restore correct operation.
impression FR10 Bar User Manual Rev. A