www.glp.de

5. Control menu layout

Menus
DMX Start Address
001-512
Protocol Setup
DMX
Protocol Type
Art-Net
sACN
Addressing Mode
Ethernet
Config
Custom IP Address
Custom IP Subnet
Art-Net Port
sACN Universe
Fixture Settings
OFF
Tilt Invert
ON
ON
Position
Feedback
OFF
OFF
Tilt Disable
Reset disable
Current disable
OFF
Zoom Invert
ON
Blackout
Hold
No Signal
Replay DMX scene
Capture DMX Values
Soft (Square)
Dimmer
Curve
Linear
OFF
Pixel Mirror
ON
24
Auto 2.X.X.X
Auto 10.X.X.X
DHCP
Custom IP
xxx.xxx.xxx.xxx
xxx.xxx.xxx.xxx
0 - 32767
1 - 63999
impression
Notes
Set fixture's DMX address
Control via DMX protocol
Control via Art-Net
protocol (default)
Control via sACN protocol
Auto addressing in the
range 2.X.X.X
Auto addressing in the
range 10.X.X.X
Get IP address by DHCP
Use custom IP address
Set custom IP address
Set custom subnet
Set Art-Net port
Set sACN universe
Reverse direction of tilt
movement
Enable/disable pan/tilt
position correction
Tilt normal
No tilt reset but DMX Tilt
control enabled
Tilt fully disabled
Zoom narrow to wide
Zoom wide to narrow
Fixture blacks out if no
DMX signal received
Fixture continues to display
current effect if no DMX
signal received
Plays the scene stored
with Capture DMX Values
(see below) if no DMX
signal received
Captures current scene
and stores it for use in
Replay DMX Scene (see
above)
Soft (square law) dimming
curve
Linear dimming curve
Pixel numbering normal 1-
10
Pixel numbering reversed
10 - 1