Section 6

Pairing with AX10RF Receiver for Zone Valve Switching (RX2)

Each system will support only one AX10RF configured as RX1 and one configured as RX2. These two
configurations can be used together to provide boiler switching and zone valve operation.
Before starting the pairing process, be sure that the AX10RF Receiver is installed as shown in the
installation instructions included with the device .
• The switch on the inside cover must be configured to RX2 .
• The LED backlight on the Auto/Manual switch of the AX10RF Receiver should be flashing red .
• The Auto/Manual switch of the AX10RF Receiver should be in the AUTO position .
• The AWRT10RF Thermostat should be powered up and flashing PAIR? RLAY_CTL .
Step 1. Press and hold the lighted red pairing
button on the AC10RF Coordinator for 5
seconds, until the LED begins to flash .
Step 2. On the AWRT10RF Thermostat,
press
until PAIR? RCV2 is displayed .
Press SELECT .
AWRT10RF Pairing without Internet
Connection (AC10RF Coordinator)
JOINING- - - will be displayed with a 10
minute countdown timer and a flashing
network status indicator .