Salus AX10RF System Manual page 57

Wireless controls system
Hide thumbs Also See for AX10RF:
Table of Contents

Advertisement

Section 8
AWRT10RF Wireless Radiant Thermostat Parameters
The table below titled AWRT10RF Wireless Radiant Thermostat Parameters lists parameters
available from the thermostat screen & keypad .
Para. #
Function
P01
Pair Device
P02
Internal Schedule
Temperature
P03
Control
Method
Minimum
P04
OFF Time
Temperature
P08
Offset
Freeze
P09
Protection
Maximum Target
P10
Temperature
Minimum Target
P11
Temperature
P15
External Sensor
External Sensor
P16
Function
Maximum Floor
P17
Temperature
Minimum Floor
P18
Temperature
AWRT10RF Thermostat Settings & Parameters
Default
Range
RLAY_CTRL
RDTR_VLV
RLAY_CTL
RCV1
RCV2
N (inactive)
N (inactive)
Y (active)
AUTO
AUTO
TPI
DLTA 1 .0/0 .5
DLTA 0 .5/0 .25
180 seconds
180 - 300 seconds
0 .0°F or °C
±6 .0°F (3 .0°C)
41 to 63°F
(5 to 17°C)
41°F (5°C)
Off
42 to 95°F
95°F (35°C)
(5 .5 to 35°C)
41 to 94°F
41°F (5°C)
(5 to 34 .5°C)
ON (Enable)
OFF (Disabled)
OFF (Disable)
FLR (Floor)
FLR (Floor)
or AIR
52 to 95°F
81°F (27°C)
(11 to 35°C)
41 to 95°F
50°F (10°C)
(5 to 35°C)
Description
AKL Relay controllers: Displays controller ID & Zone number
ARV/AVA Valve Actuators: Displays total # of paired valves
AX10RF Receiver (RX1): Cn = Connected
AX10RF Receiver (RX2): Cn = Connected
Settings S 03 through S 10 are not available
Schedule Mode
RLAY CTL (HEAT), RCV1, RCV2 = TPI
RLAY CTRL (COOL) = DLTA 1 .0°F (0 .5°C)
RDTR VLV = DLTA 0 .5°F (0 .25°C)
TPI control is based on the current temperature differential
(Proportional) and historical performance (Integral) to determine the
next duty cycle percentage .
Heat turns on when T
= T
room
setpoint
T
= T
+ Delta
room
setpoint
Minimum period that the thermostat must be off before starting a new
cycle to prevent short cycling . (TPI Only)
Temperature offset for current active temperature sensor
Minimum allowable temperature for the system . Below the
specified temperature a heat demand will be signaled .
Maximum allowable temperature setting for heating and cooling mode .
Minimum allowable temperature setting for heating and cooling mode .
Enable or Disable external sensor for remote sensing . "EXTERNAL" is
only displayed if P16 function is set to "AIR" .
Floor temperature is used to control the room temperature based on
the room and radiant floor temperature .
Air is used when a remote sensor is used in place of the internal
thermostat sensor .
Maximum temperature that a heat demand will be signaled . P15
must be ON and External Sensor Function must be FLR . Not
displayed for RDTR VLV .
Minimum temperature that a cooling demand will be signaled .
P15 must be ON and External Sensor Function must be FLR . Not
displayed for RDTR VLV .
– Delta, Cooling turns on when
8 .3