Akl01Prf Zone Pump Wiring Center Installation - Salus AX10RF System Manual

Wireless controls system
Hide thumbs Also See for AX10RF:
Table of Contents

Advertisement

Section 3

AKL01PRF Zone Pump Wiring Center Installation

The AKL01PRF 1-Zone Pump Wiring Center pairs with an AWRT10RF Wireless Thermostat via the SG888ZB
Gateway or AC10RF Coordinator to provide a heat demand signal to the boiler and control a zone pump .
The AKL01PRF Single Zone Pump Wiring Center must be installed by a qualified contractor. Installation
and repairs are to be performed according to all national and local codes required by the authority
having jurisdiction. In the absence of local requirements, follow ANSI/NFPA 70, National Electrical
Code. Failure to follow these requirements may lead to severe personal injury, death or major property
damage. DO NOT SERVICE this equipment without disconnecting the AC electrical power.
1 . Carefully read these instructions and all instructions supplied
with the unit before starting the installation .
2 . Inspect the control for damage and be sure all required parts
are included before beginning .
3 . Remove 4 screws at the corners and lift off the plastic cover .
4 . Check that the fuse installed is a 5A, slow blow fuse and that it
is inserted correctly .
5 . Attach the base of the AKL01PRF Zone Pump Wiring Center to
a wall or similar vertical structure in a suitable location near the
boiler and pumps using the hardware supplied .
DO NOT INSTALL this control in an area where water leaks or spray are
possible. Failure to comply may result in serious injury, death or major
property damage due to electrocution or fire.
6 . BE SURE all electrical power to the device is disconnected before wiring the device .
7 . Wire 120 VAC power to the L (Hot), N (Neutral) and
8 . Wire the 120 VAC power output to the pump from L (Hot), N (Neutral) terminals labeled,
"PUMP" . Connect the ground terminal to the "POWER IN"
in the wiring schematic .
9 . Wire the output terminals labeled "XX" to the boiler thermostat input ("TT") .
10 . Wire the thermostat contacts to R & W on the terminals labeled "24 VAC T-STAT" . If a "C" wire
is required connect it according to the drawing .
11 . Reattach the control cover securing it with the 4 screws and switch on 120 VAC power to
the unit . The LED labeled "POWER" will be illuminated .
Device Installation
Warning
• This product must be installed by qualified personnel and the installation must comply with the codes and regulation
municipality where this product is installed. Failure to do so could lead to injury, death, or prosecution.
• Always disconnect the AC power before installing or working on AC power components.
For PDF Installation guide go to
www.salusinc.com
AKL01PRF ZigBee Zone Pump W
(Ground) terminals labeled, "POWER IN" .
(Ground) terminal as shown
Technical Helpline 1-855-557-2587
Electrical Connections
Dry Contacts (rated 120VAC, max.2A)
XX Active Pump
120VAC Connections
AC Line In
L
Zone Pump Line Out (max. 1/6 HP)
N
AC Neutral
Earth Ground
Fuse: 5A slow blow, 5x15mm (2AG)
Operational Summary
Zone Pump
The zone pump will be activated when
the thermostat calls for heat.
Auxiliary Output
XX: Contact closure when zone pump is ON.
Factory Default
To restore the wiring center to Factory Default,
press and hold the Pair button until the
Network Status LED turns off (~10 secs).
Note: Restoring to Factory Default will remove
the wiring center from the network and delete
all associated devices.
LED In
Name
Power
Zone 1
Network
Status
Wiring
Zone L
short=1
3 .6