Verification Check for a FrameSaver 9124, 9126, or 9128:
-
Check the Network LEDs. Is the Sig (signal) LED on, and are the OOF (out of
frame), and ALM (alarm) LEDs off?
– If yes, the network interface is set up correctly and is ready to pass data.
– If no, check that both ends of the network cable are properly seated, then verify
that the network physical options are configured correctly.
Main Menu
-
Check Health and Status messages in the left column of the System and Test
Status screen to see the LMI status, to verify that LMI is up.
Main Menu
– If LMI Down, Network appears for more than three minutes, or any other
network-related status message appears, refer to the status information in
Displaying System Information of the User's Guide for possible reasons for the
messages and what can be done to resolve the problem.
Verification Check for a FrameSaver 9624:
-
Is the Network OOF/ NS (out of frame/no signal) and ALM (alarm) LEDs off?
– If yes, the network interface is set up correctly and is ready to pass data.
– If no, check that both ends of the network cable are properly seated, then verify
that the network physical options are configured correctly.
Main Menu
-
Check Health and Status messages in the left column of the System and Test
Status screen to see the LMI status, to verify that LMI is up.
Main Menu
– If LMI Down, Network appears for more than three minutes, or any other
network-related status message appears, refer to the status information in
Displaying System Information of the User's Guide.