Paradyne FrameSaver SLV Series Installation Instructions Manual page 22

1-slot unit
Table of Contents

Advertisement

Connecting to the DSX
This procedure does not apply to the FrameSaver 9624.
If installing a FrameSaver 9126 unit, a DSX adapter is provided as an interface
between the unit's modular RJ48C DSX connector and a CPE (customer premises
equipment, like a PBX). Select the appropriate procedure.
FrameSaver 9124 or 9128:
1. Connect the DB15 end of the DSX cable to the DSX-1 interface.
2. Connect the other end of the cable to the CPE (customer premises equipment,
like a PBX).
3. Tighten the screws on each side of the connector to secure them.
POWER
FrameSaver 9126:
1. Connect the RJ48C end of the DSX adapter to the DSX-1 interface.
2. Connect the other end of the DSX adapter to the DB15 end of the DSX cable.
3. Connect the other end of the DSX cable to the CPE.
4. Tighten the screws on each side of the connector to secure them.
Verification Check:
-
Check the DSX LEDs. Is the Sig (DSX-1 signal) LED on, and are the DSX-1 OOF
(out of frame) and ALM (alarm) LEDs off?
– If yes, the DSX interface is set up correctly and ready to communicate.
– If no, check that both ends of the DSX cable are properly seated and secured.
– If OOF, match the Line Framing Format and Line Coding Format options to the
network provider's settings.
– If EER (excessive error rate), contact the service provider.
-
Check Health and Status messages in the left column of the System and Test
Status screen to verify that there are no DSX-1 Health and Status messages.
– If any DSX-1 messages appear, refer to the status information in Displaying
System Information of the User's Guide.
See Displaying System Information in the User's Guide for additional status
information, and Troubleshooting for additional troubleshooting information.
COM
(FrameSaver 9124
Shown)
DSX-1
NETWORK
22
PBX
98-15827

Advertisement

Table of Contents
loading

Table of Contents