Locating The Connecting Box For Connection Cable In The Sauna Room; Sauna Heater Safety Clearances; Image 2 Location For The Connecting Box - Helo ROCHER Instructions For Installation And Use Manual

Electric sauna heater
Table of Contents

Advertisement

Table 1
Input
Sauna heater's
connection cable
H07RN-F
60245 IEC 66
kW
mm
400 - 415V 3N~
6,8
5 x 1,5
9,0
5 x 2,5
10,5
5 x 2,5

3.5 Locating the connecting box for connection cable in the sauna room

A
Image 2
A = Speficed minimum clearance
1. Recommended location for the connecting box
2.
Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connecting
box must be clear of obstacles. When installing the connecting box to zones 2 or 3, refer to the
instructions and regulations of the local energy supplier.
3.6 Sauna heater
safety clearances
Table 2
Fuse
Sauna heater's
connection cable
H07RN-F/
60245 IEC 66
A
2
230 V 3~
3 x 10
4 x 2,5
3 x 16
4 x 6
3 x 16
4 x 6
Sauna room
kW
m
m
3
3
6,8
5
9
9,0
8
13
10,5
9
15
Fuse
mm
A
2
230 - 240V 1N~ / 2~
3 x 16
3 x 25
3 x 35
A
3.
2.
Safety clearances
min.
H
A
D
mm
mm
mm
1900
60
60
1900
60
60
1900
60
60
Sauna heater's
Fuse
connection cable
H07RN-F/
60245 IEC 66
mm
A
2
3 x 6
1 x 35
-------
-----
-------
-----
1.
F
mm
ca.kg
770
100
770
100
770
100
8