1. Quick start guide for the sauna heater

1.1 Check the following before taking a sauna bath:
-
The sauna room is suitable for taking a sauna bath.
-
The door and the window are closed.
-
The sauna heater is topped with stones that comply with the manufacturer's recommendations,
the heating elements are covered with stones, and the stones are piled sparsely.
NOTE: Structural clay tiles are not allowed.

1.2 Operation of the sauna heater controls

Refer to the specific control panel operating instructions.

2. Information for users

Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge
about how the device is operated (e.g. children), should only operate the device while supervised or
accoding to instructions given by the persons in charge of their safety.
Make sure that children are not playing with the sauna heater.

2.1 Sauna room

The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such
as tile and stone surfaces must be insulated. It is recommended to use wooden panel cladding inside the
sauna room. If there are heat storing elements in the sauna room, such as decorative stone, glass etc., note
that these elements may extend the pre-heating period even though the saunaroom is otherwise well
insulated. (see page 6, section 3.1 Preparing for sauna heater installation)

2.2 Recommended sauna room ventilation

5
4
6
2
1. Sauna room
3. Electric sauna heater
2. Washroom
4. Exhaust valve
7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing.
Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with (i.e. cool down) the sauna
heater's thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn't fitted with forced ventilation. In this case, the exhaust valve
is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER'S CONTROL THERMOSTAT IS
LOCATED AT THE SAME ZONE.
5
7
1
1
4
C
C
C
C
1000 mm
B
B
3
3
5. Exhaust flue or channel
6. Door to the sauna room
A
A
A
min
200 mm
1
3