Appendix C Interfaces - Epson TM-300A Operator's Manual

1 station printer
Table of Contents

Advertisement

APPENDIX C Interfaces

n
TM-300A/B
1. Specifications (RS-232C compatible)
Data transmission: Serial
Synchronization: Asynchronous
Handshaking:
Signal level:
Baud rates:
Bit length:
Parity:
Stop bits:
Connector:
2. Interface connector terminal assignments and signal functions
Pin Number
Signal Name
FG (GND)
1
2
SD (TXD)
3
RD (RXD)
4
RS (RTS)
5
DR (DSR)
7
SG (GND)
DTR/DSR or XON/XOFF control
MARK = -3 to -15 V:
SPACE = +3 to + 15 V:
1200, 2400, 4800, 9600 bps
7 or 8 bits
None, even, odd
or more (data transmitted from
1
stop bit.)
D-SUB 25 (female) or equivalent
Signal Direction
-
Frame ground
output
Transmit data
Input
Receive data
output
The same signal as DTR
This signal indicates whether the host
Input
computer can or cannot receive data.
"SPACE" indicates that the host com-
puter can receive data and MARK
indicates that the host computer cannot
receive data.
When DTF/DSR control is selected, the
printer transmits data after checking this
signal.
When XON/XOFF control is selected, the
printer does not check this signal.
-
Signal ground
56
Logic "1"
Logic "0"
printer has 1
the
Function