ADA-13021MG

5.2.6.4. FACTORY DEFAULT SETTINGS

The converter was configured by the manufacturer.
To restore factory default settings, select from menu Factory Default Settings. After that the converter will automatically reboot.
5.2.6.5. SYSTEM INFORMATION
Section System Information displays:
- General – device model, MAC address, firmware version, Boot version, POST version and more.
- GPIO – not applicable in ADA-13021MG.
- Serial – port description, current settings of serial port, status of controlling lines and the statistics data transfer through serial port.
- Network – show statistics of ETHERNET interface for IP, TCP, UDP, ICM protocols.
5.2.6.6. REBOOT
Section Reboot allows making software reset of ADA-13021MG. Pressing [Reboot] will start rebooting of server during 1 min.
5.2.6.7. LOGOUT – ENDING MANAGEMENT AND CONFIGURATION
After completion of the configuration or administration should be pressing Logout on left panel – logout from WWW server of ADA-
13021MG converter.
6. USING VIRTUAL PORT SERVICE [REALPORT]
6.1. VIRTUAL PORT DRIVER INSTALLATION IN WINDOWS XP
The installation of virtual serial port drivers should be done for the CD, by choosing:
-Drivers/Win-98-ME, for Windows 98, Windows 98SE, Windows ME,
-Drivers/Win-2000, for Windows2000,
-Drivers/Win Server-2003-2008-2012 for Windows Server 2003, 2008, 2012,
-Drivers/Win-Vista for Windows Vista.
-Drivers\Windows\Win XP-7-8-8.1-10 for Windows XP, 7, 8.x, 10.
Installation of Virtual serial port drivers is as follows:
1. Connect ADA-13021MG to ETHERNET and power,
2. Press [Start] and select [Run...],
3.
In the dialog window [Run] press [ Browse ],
4. Select „My computer" and CD-Rom with „ADANET_DRV",
5. Select catalog Drivers/WinXP2003Vista_x86_x64,
6. Select file „Setup32.exe" for 32-bits system or „Setup64.exe" for 64-bits and press [Open],
7. When the installation window will appear press [Next],
8. Will start the searching for converters in the network, found devices will be added to the list.
9. Select the converter from the list for installation of virtual port driver and press [Next].
10. In window Describe the device select or not the Starting Com port and press [Finish]. The driver will be installed.
The Virtual Serial Port Drivers can be installed without connection of ADA-13021MG to ETHERNET and it is as follows:
1.
Press [Start] button, select [Run...]
2. In the dialog window [Run] press [ Browse ]
3. Select „My computer" and CD-Rom with „ADANET_DRV".
4. Select catalog Drivers/WinXP2003Vista_x86_x64.
5. Select file „Setup32.exe" for 32-bits system or „Setup64.exe" for 64-bits and press [Open].
6. When the installation window will appear press [Next] .
7. Will start the searching for converters in the network.
8. If no devices were not found press [Next].
9. Should be set in the window Describe the device:
– IP address for converter,
– number of installing COM port (No. Ports)
– Starting COM
and press [Finish]. The driver will be installed.
In this way installed virtual port can require the configuration in case of connecting the converter to network.
6.2. REALPORT CONFIGURATION IN WINDOWS XP
After installation of RealPort drivers, can be done configuration by the use the Device Manager of Windows and it is as follows:
1. Press [Start], select [ Properties/Setting ], press [ Control Panel ].
2. Double click icon [ Administrative Tools] and [ Device Manager ]
3. Press [Ports (COM & LPT)]. On fig. 34 is shown available serial ports COM1, COM2 and COM3 marked as ADA-13021MG which
was created after installation of RealPort driver.
4. Then select [Multi-port Serial Adapter], there will be the name ADA-13021MG.
5. Double click the name and the window [Properties] will appear.
6. Select [Advanced] and press [Properties].
7. Enter new name of virtual port for converter. In the window [Advanced Properties] click [ADA-13021MG] and then select
[Properties], press [Rename Ports], now it is possible to change the name of virtual port driver for example COM5, COM11 etc. To
accept the changes press [OK].
8. Select IP address, MAC, DNS server for communication with virtual port driver. In the window [ Advanced Properties] click
[ADA-13021MG] and then select [Network] (Fig. 35), and set the IP address, MAC Address or DNS name of converter for
28