Changing User Mane And Password; Adding New User With Limited Permissions For Configuration Or Management; Management; Serial Ports Management - CEL-MAR ADA-13021MG User Manual

Current loop to ethernet converter with modbus gateway
Table of Contents

Advertisement

ADA-13021MG
– Configure Users
The section Users allows configuring the method of login to ADA-13110MG. Selecting the option Enable user logins means that after
enter the address
http://<ip- c on v erter- address >/admin/administration.htm
necessary to enter user name and password.
Section Configure Users allows adding additional user, change password, configure access and permissions for each defined users.

5.2.4.1. CHANGING USER MANE AND PASSWORD

Changing the default user root and password, can be done as follows :
1. press user mane root in section Users Configuration->Configure Users,
2. enter new user name and password.
3. press [Apply] for saving.
5.2.4.2. ADDING NEW USER WITH LIMITED PERMISSIONS FOR CONFIGURATION OR

MANAGEMENT

For adding new user with limited permissions for configuration or management of the converter, follow the steps below:
1.From menu Configuration select Users,
2. In section Configure Users, press [New...],
3. Enter user mane (eg. admin) and password – twice, and press [Apply],
Will open the page Users Configuration, where in section Configure Users, will be new user name.
Now it is possible to configure access permissions to the converter and permissions for configuration of this new user.
Configuration of access to converter:
1.From menu Configuration select Users,
2. In section Configure Users, select added user eg. admin,
3. Will open the page User Configuration – admin, where are sections:
A/ User Configuration – possibility of rename user and password,
B/ User Access - method of access to converter from the network:
Allow command line access – access using the Command Line Interface - telnet,
Allow web interface access – access using the internet browser.
C/ User Permissions - user permissions to configuration and management of the ADA-13021MG converter, where are options:
None - no permission,
Read - permission to read,
Read Self - permission to read own settings, but not other users.
Read/Write - full permission to read and write the setting.
Read/Write Self - permission to read and write own setting, but not other users.
Read All/Write Self - permission to read the setting for all users and modify only own setting (not other users).
Execute - permission to execute (start).
4. All changes are saved by pressing [Apply].
5.2.5. MANAGEMENT
On left panel in menu Management are to sections :
- Serial Ports
- Connections

5.2.5.1. SERIAL PORTS MANAGEMENT

Section Serial Ports allows to identification connections/disconnection to the serial port of the converter through the network.

5.2.5.2. CONNECTIONS MANAGEMENT

Section Connections allows to identification connections/disconnection to the converter through the network.

5.2.6. ADMINISTRATION

The menu Administration allows :
– to delete/upload files with Java applet,
– to backup/restore configuration of converter,
– to update Firmware,
– to restore the factory default settings,
– to display system details information,
– to reboot the converter.

5.2.6.1. FILE MANAGEMENT

Section File Management enables upload and delete Web provided by manufacturer. Uploaded index.htm or index.html allows to
automatically run the page in the web browser after entering
13021MG.
5.2.6.2. BACKUP & RESTORE CONFIGURATION
Section Backup/Restore enables backup to file or restore from file the user configuration of the converter.

5.2.6.3. FIRMWARE UPDATE

Section Update Firmware enables to make the update firmware from the file. Firstly should be done update the POST software before
updating the firmware – more details available on the web page
to internet browser, will open login window and will be
http://ip-converter-address/FS/WEB/index.htm
http://www.cel-mar.pl
27
and login to ADA-

Advertisement

Table of Contents
loading