1.1. GUARANTEE INFORMATION ADA-13028L converter is covered by a two year warranty from date of sale. In case of being damaged it will be repair or the damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any unauthorized changes.
2.2. DESCRIPTION ADA-13028L converter is use for data transmission between devices equip with CLO Current Loop interface via LAN/WAN network. Operating in ETHERNET network can be in Virtual Serial Port mode, TCP serial bridge mode, UDP serial bridge mode. Converter can use protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP.
3.1. ASSEMBLING ADA-13028L converter case is adapted to assembly on TS-35 (DIN35) rail. To install the device on TS-35 should be the upper part of the casing put hooks on the terminal and then press the bottom of the cover until you hear a characteristic "Click" sound.
3.2.1. CONNECTING TO NETWORK ADAPTER OF PC If there is not the switch or the HUB, it is possible to connect the ADA-13028L directly to a network adapter of PC using the cross-over cable (Table 2). This connection can be used for converter configuration.
ADA-13028L 3.2.2. CONNECTING FOR REALPORT MODE OPERATING Fig. 4 (above) and 5, 6 below show how correctly connect the ADA-13028L to LAN, WAN network or PC to operating in virtual serial port mode (RealPort). For direct connection of the converter to PC network adapter, use the cross-over cable (see Table 2) and for connection by the use of switch or HUB use the straight cable (see Table 1).
ADA-13028L 3.2.3. CONNECTION FOR FUNCTIONING IN TCP AND UDP SERIAL BRIDGE MODE Fig. 7 and 8 show how correctly connect ADA-13028L converter to Ethernet network for functioning in TCP and UDP serial bridge mode. For connection by the use of network devices (router, switch or HUB) use the straight cable (see Table 1).
CLO+ CLO+ RJ-45 CLO- CLO- Power Power Fig.9a. Example of connecting a device with passive CLO interface to ADA-13028L 3.3.2. CONNECTION OF DEVICE WITH ACTIVE CLO INTERFACE Device with ADA-13028L ACTIVE CLO PASSIVE CLO interface interface ETHERNET...
ADA-13028L 3.3.3. CONNECTION OF ENERGY METER WITH CLO INTERFACE (IEC 62056-21) The following drawing shows how to connect energy meter with CLO interface (IEC 62056-21) to ADA-13028L-1-1-1-A-2-3. Device with CLO interface ADA-13028L ETHERNET connector terminal CLO+ RJ-45 Current Loop 0-20 mA...
3.3.4. CONNECTION OF FOUR ENERGY METER WITH CLO INTERFACE (IEC 62056-21) The following drawing shows how to connect max. four energy meter with CLO interface (IEC 62056-21) to ADA-13028L-1-1-1-A-2-3. Fig. 10b. Example of connecting four energy meter with CLO interface to ADA-13028L-1-1-1-A-2-3...
3.4. POWER SUPPLY CONNECTION The power supply to the ADA-13028L should be DC (regulated) from the scope 10 V= to 30V= and nominal power more than 3W e.g. HDR-15-24. Power cable from DC power supplies to device must not be longer than 3m. Observe the polarity, connect positive (+) of DC power supplies to V+ and negative (-) end to V- terminal.
Page 14
ADA-13028L Fig 11. Basic network configuration using ADAFinder Fig 12. IP address setting...
5.2.1. NETWORK SETTING CONFIGURATION To make changes of default setting or new configuration of ADA-13028L, select on left panel Configuration -> Network and then on right [IP Settings] (Fig.14) and make the selection: Obtain an IP address automatically using DHCP or Use the following IP address (in this option, enter IP Address of the converter, Subnet Mask, Default Gateway), press [Apply] for save.
Fig 14. Page for network setting configuration of ADA-13028L converter 5.2.2. SERIAL PORT CONFIGURATION The configuration of serial port of the ADA-13028L converter includes: port description, setting of port profile (operating mode) and setting of serial transmission parameters (baud rate, data bits, parity, stop bits).
5.2.2.1.2. TCP SOCKETS CONFIGURATION Choosing TCP Sockets, is configured the serial port of ADA-13028L, for direct communication with PC by the use of TCP socked. Data sending by application to TCP socked are transferred through network to ADA-13028L converter and are present on his serial port.
ADA-13028L Fig 16. Example configuration of TCP server For configuration of TCP Client Settings (Fig 17), select Automatically establish TCP connections, connection between client and TCP server will be automatically. Then select Always connect and maintain connection option and in section Establish connection to the following network service enter IP address of device to which TCP client will send data, select service and enter port.
ADA-13028L For proper operation of ADA-13028L with device connected to his Current Loop serial port, should be set the same transmission parameters for both devices. Select Basic Serial Settings and enter Baud Rate, Data Bits, Parity, Stop Bits, the same parameter like has device connected to the serial port of the converter.
ADA-13028L Set operating parameters of UDP server for SLAVE device connected via serial port to ADA-13028L, eg like on picture below. Set access to UDP server on e.g. 2101 port. Then select Automatically send serial data in section UDP Client Settings, this automatically send received data by the use UDP client service to the MASTER device connected to LAN / WAN through e.g.
After saving the Serial Bridge profile, will open section Serial Bridge Settings (fig.20) with operating parameters like on picture below. Select Initiate serial bridge to the following device option and enter IP address and 2101 Port of ADA-13028L with which to create the serial bridge over the network.
- Network – show statistics of ETHERNET interface for IP, TCP, UDP, ICM protocols. 5.2.6.6. REBOOT Section Reboot allows making software reset of ADA-13028L. Pressing [Reboot] will start rebooting of server during 1 min. 5.2.6.7. LOGOUT – ENDING MANAGEMENT AND CONFIGURATION After completion of the configuration or administration should be pressing Logout on left panel –...
2. Double click icon [ Administrative Tools] and [ Device Manager ] 3. Press [Ports (COM & LPT)]. On fig. 28 are shown available serial ports COM1, COM2 and COM3 marked as ADA-13028L which was created after installation of RealPort driver.
Page 24
ADA-13028L Fig 26. Device view on Windows XP system. Fig 27. Configuration of multi-port series adapter.
Page 25
Order example of converter for energy Current Loop Current: meter with CLO interface (IEC 62056-21): 0 – 20 mA (standard) Prod. symbol : ADA-13028L-1-1-1-A-2-3 0 – 30 mA 1 – standard electronic version, 0 – 45 mA 1 – current loop voltage 24VDC, 1 –...
Page 26
ADA-13028L 10. SPECIFICATION TECHNICAL DATA Transmission Parameters Interface ETHERNET Current Loop CLO Screw terminal, wire diameter max Connector RJ45 2,5mm Depend on baud rate up to few hundred Line length LAN up to 150 m meters Depend on addressing type setting in the 2 point-to-point or 15 in Current Loop Max.
Page 28
Thank you for purchasing CEL-MAR Company product. We hope that this user manual helped connect and start up the ADA-13028L converter. We also wish to inform you that we are a manufacturer of the widest selections of data communications products in the world such as: data transmission converters with interface RS232, RS485, RS422, USB, Ethernet, Wi-Fi, Current Loop, Fibre-Optic Converters and the other.