Led Blink Codes - LinMot C1250 Series Installation Manual

Table of Contents

Advertisement

Installation Guide C1250

9 LED Blink Codes

LED Blink Codes
Error
Warn
Off
Warning
On
● ~2 Hz
0..15 x
Error Code
High Nibble
● ~2 Hz
● ~2 Hz
0..15 x
Error Code
High Nibble
● ~4 Hz
● ~2 Hz
0..15 x
Error Code
High Nibble
● ~0.5 Hz
● ~0.5 Hz
Off
○●●●
○●
●○
~4 Hz
~4 Hz
Off
○ ●
~2 Hz
On
On
The meaning of the error codes can be found in the Usermanual_MotionCtrl_Software_SG5-SG7 and the user
manual of the installed interface software. These documents are provided together with LinMot-Talk
configuration software and can be downloaded from www.linmot.com.
NTI AG / LinMot
EN
Description
Operation
Normal Operation:
Enabled
Warnings and operation enabled are displayed.
● ~2 Hz
Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN"
Error Code
The error byte is divided into low and high nibble (= 4 bit).
Low Nibble
"WARN" and "EN" are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2 Hz
Fatal Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN".
Error Code
The error byte is divided into low and high nibble.
Low Nibble
"WARN" and "EN" are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2 Hz
System Error:
0..15 x
Please reinstall firmware or contact support.
Error Code
Low Nibble
On
Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal supply +24 VDC (X4.2) is less
than 18 VDC.
●○●●
Plug&Play Communication Active:
This sequence (Warn on, then En on, then both off, complete sequence of the 4 states
ca. 1 s) signalizes the state when the plug and play parameters are being read from
the motor.
Off
Waiting for Defaulting Parameters:
When ID (S1, S2) is set to 0xFF, the drive starts up in a special mode and the Error
and Warn LED blink alternating ~4 Hz. When the ID ist set to 0x00, all parameters will
be set to their default value. To leave this state, power down the drive and change the
ID. Also see in the Usermanual_LinMot-Talk under chapter trouble shooting.
○●
Defaulting Parameters Done:
~2 Hz
When the parameters have set to their default values (initiated via S1/S2 on power up)
the Warn and En LEDs blink together at 2 Hz. To leave this state, power down the
drive. Also see in the Usermanual_LinMot-Talk under chapter trouble shooting.
On
Bootstrap
If also both RT LEDs are on, the drive is in the bootstrap mode. Set S5 to off.
0185-1063-E_6V16_IG_Drives_C1250