Error Codes - LinMot E1200 Installation Manual

Hide thumbs Also See for E1200:
Table of Contents

Advertisement

LinMot Installation Guide

Error Codes

7
Error
Warn
Off
Warning
On
● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
● ~4Hz
0..15 x
Error Code
High Nibble
● ~0.5Hz
● ~0.5Hz
Off
M●●●
M●
●M
~4Hz
~4Hz
Off
M●
~2Hz
The meaning of the error codes can be found in the Usermanual_MotionCtrlSW_SG5
and the user manual of the installed interface software. These documents are
provided together with LinMot-Talk configuration software and can be downloaded
from www.linmot.com.
NTI AG / LinMot
®
Error Codes
EN
Operation
Normal Operation:
Enabled
Warnings and operation enabled are displayed.
● ~2Hz
Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN".
Error Code
The error byte is divided into low and high nibble (= 4 bit).
Low Nibble
"WARN" and "EN" are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2Hz
Fatal Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN".
Error Code
The error byte is divided into low and high nibble.
Low Nibble
"WARN" and "EN" are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2Hz
System Error:
0..15 x
Please reinstall firmware or contact support.
Error Code
Low Nibble
On
Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal supply +24V (X4.2) is
less than 18VDC.
Plug&Play Communication Active
●M●●
This sequence (Warn on, then En on, then both off, complete sequence of the 4
states ca. 1Sec) signalizes the state when the plug and play parameters are
being read from the motor.
off
Waiting for Defaulting Parameters
When ID (S1, S2) is set to 0xFF, the drive starts up in a special mode and the
Error and Warn LED blink alternating ~4Hz. When the ID ist set to 0x00, all
parameters will be set to their default value. To leave this state, power down the
drive and change the ID. Also see in the Usermanual_LinMot-Talk under
chapter trouble shooting.
Defaulting Parameters Done
M●
When the parameters have set to their default values (initiated via S1/S2 on
~2Hz
power up) the Warn and En LEDs blink together at 2 Hz. To leave this state,
power down the drive. Also see in the Usermanual_LinMot-Talk under chapter
trouble shooting.
www.LinMot.com
Description
Page 15/22