Installation Guide C1250
8.6 X17 – X18
X17 – X18
RealTime Ethernet 10/100 Mbit/s
X17 RT ETH In
X18 RT ETH Out
RJ-45

8.7 X19

X19
System
RJ-45
Use isolated USB-RS232 converter (Art.-No. 0150-2473) for configuration over RS232

8.8 X33

X33
Spring cage connector (has
to be ordered separately:
see chapter 15)
8.9 S1 – S2
S1 – S2
Address Selectors
S1 (5..8)
S2 (1..4)
The use of these switches depends on the type of fieldbus which is used. Please see the corresponding manual for
further information.
NTI AG / LinMot
Specification depends on RT Bus. Please refer to according documentation.
1
(Do not connect)
2
(Do not connect)
3
RS232 Rx
4
GND
5
GND
6
RS232 Tx
7
(Do not connect)
8
(Do not connect)
case
Shield
Safety Relays (only with the -1S option)
4 / 8
Ksr +
3 / 7
Ksr -
2 / 6
Ksr f+
1 / 5
Ksr f-
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm
- Stripping length: 10mm
- The state of the feedback contacts has to be checked after each change of the state of the control
contacts!
- Never connect the safety relays to the logic supply of the drive!
→ For detailed information see chapter 10 Safety Wiring.
Bus ID High (0 ... F). Bit 5 is the LSB, bit 8 the MSB.
Bus ID Low (0 ... F). Bit 1 is the LSB, bit 4 the MSB.
Setting the ID high & low to 0xFF resets the drive to manufacturer settings!
0185-1063-E_6V16_IG_Drives_C1250
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative