Axis A1601 User Manual page 15

Network door controller
Hide thumbs Also See for A1601:
Table of Contents

Advertisement

AXIS A1601 Network Door Controller
System configuration
5. Depending on what lock manufacturer you got, proceed according to one of the bullets:
-
ASSA Aperio: Click the link to view the hardware pin chart or click Close and go to Setup > Hardware
Reconfiguration to complete the configuration, see Add Assa Aperio
-
SmartIntego: Click the link to view the hardware pin chart or click Click here to select wireless gateway and
configure doors to complete the configuration, see How To Configure SmartIntego on page 19.
TM
Add Assa Aperio
doors and devices
Before adding a wireless door to the system it needs to be paired with the connected Assa Aperio communication hub, using
Aperio PAP (Aperio programming application tool).
To add a wireless door:
1. Go to Setup > Hardware Reconfiguration.
2. Under Wireless Doors and Devices click Add door.
3. In the Door name field: Enter a descriptive name.
4. In the ID field under Lock: Enter the six-character-long address of the device that you want to add. The device address is
printed on the product label.
5. Optionally, under Door position sensor: Choose Built in door position sensor or External door position sensor.
Note
If using an external door position sensor (DPS), make sure that the Aperio lock device has support for door handle state
detection before configuring it.
6. Optionally, in the ID field under Door position sensor: Enter the six-character-long address of the device that you want to
add. The device address is printed on the product label.
7. Click Add.
How to create a new hardware configuration with elevator control (AXIS A9188)
Important
Before creating a HW configuration you need to add a user in AXIS A9188 Network I/O Relay Module. Go to the A9188 web
interface > Preferences > Additional device configuration > Basic setup > Users > Add > User setup.
Note
Max 2 AXIS 9188 Network I/O Relay Modules can be configured with each Axis Network Door Controller
1. In the door controller's web page, go to Setup > Hardware Configuration and click Start new hardware configuration.
2. Enter a name for the Axis product.
3. In the list of peripherals, select Elevator control to include an AXIS A9188 Network I/O Relay Module and click Next.
4. Enter a name for the connected reader.
5. Select the reader protocol that will be used and click Finish.
6. Click Network Peripherals to complete the configuration see How to add and setup network peripherals on page 16 or
click the link to go to the hardware pin chart.
TM
doors and devices on page 15
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents