AXIS A1601 Network Door Controller
System configuration
How to create a new hardware configuration without peripherals
1. Go to Setup > Hardware Configuration and click Start new hardware configuration.
2. Enter a name for the Axis product.
3. Select the number of connected doors and click Next.
4. Configure the door monitors (door position sensors) and locks according to your requirements and click Next. For more
information about the available options, see How to configure door monitors and locks on page 12.
5. Configure the readers and REX devices that will be used and click Finish. For more information about the available options,
see How to configure readers and REX devices on page 13.
6. Click Close or click the link to view the hardware pin chart.
How to configure door monitors and locks
When you have selected a door option in the new hardware configuration, you can configure the door monitors and locks.
1. If a door monitor will be used, select Door monitor and then select the option that matches how the door monitor
circuits will be connected.
2. If the door lock shall lock immediately after the door has been opened, select Cancel access time once door is opened.
If you want to delay the relock, set the time of the delay in milliseconds in Relock time.
3. Specify the door monitor time options or, if no door monitor will be used, the lock time options.
4. Select the options that match how the lock circuits will be connected.
5. If a lock monitor will be used, select Lock monitor and then select the options that match how the lock monitor circuits
will be connected.
6. If the input connections from readers, REX devices, and door monitors shall be supervised, select Enable supervised inputs.
For more information, see How to use supervised inputs on page 14.
Note
• Most lock, door monitor, and reader options can be changed without resetting and starting a new hardware configuration.
Go to Setup > Hardware Reconfiguration.
• You can connect one lock monitor per door controller. So if you use double-lock doors, only one of the locks can have a lock
monitor. If two doors are connected to the same door controller, lock monitors cannot be used.
About door monitor and time options
The following door monitor options are available:
Door monitor – Selected by default. Each door has its own door monitor that, for example, will signal when the door has
been forced open or open too long. Deselect if no door monitor will be used.
-
Open circuit = Closed door – Select if the door monitor circuit is normally open. The door monitor gives the door
open signal when the circuit is closed. The door monitor gives the door closed signal when the circuit is open.
-
Open circuit = Open door – Select if the door monitor circuit is normally closed. The door monitor gives the door
open signal when the circuit is open. The door monitor gives the door closed signal when the circuit is closed.
Cancel access time once door is opened – Select to prevent tailgating. The lock will be locked as soon as the door
monitor indicates that the door has been opened.
The following door time options are always available: