Light Ring Color Codes - Wacker Neuson RT82-SC3 Operator's Manual

Table of Contents

Advertisement

Operation
4.12

Light Ring Color Codes

Color—Code
Amber—solid
Amber—slow flash
Amber—fast flash
Red—solid
Red—slow flash
Red—fast flash
Mode
Non communication
Normal operation
Operator safety
Machine shut down
Automatic glow plug
Over voltage
54
Reason / Remedy
Machine's key in ON position, but:
Transmitter is not turned on.
Transmitter battery is dead.
Transmitter not pointed at machine.
Transmitter too far from machine.
Transmitter and decoder are on different
channels.
Communication fault (see topic
Communication Faults)
Machine is receiving proper signal from
transmitter and is operational.
Machine is receiving signal but operator is
too close to machine.
Move farther than two meters (6 feet)
from machine until amber lights flash
slowly.
Critical error has occurred such as: tip over,
low oil pressure, or high coolant
temperature.
For tip over: Turn key OFF, upright
machine. See topic Resetting the ECM
Diagnostic Data and theTip-Over Light.
For low oil pressure: Turn key OFF.
Check oil. Restart as normal.
For high coolant temperature: Turn key
OFF. Allow machine to cool. Add coolant.
Glow plugs are preheating engine. No
functions allowed until preheat cycle is
complete.
Machine is receiving more than 18 Volts
due to non-12V system used for jump
starting.
Replace machine's 12V battery.
Do not jump-start the machine.
RT / RTx