3. Pull up eight panel cover pawls on the reverse side of the operation panel unit. Gap between
the operation panel unit and the panel cover. Remove the panel cover.
Never scratch surfaces obvious to users.
4. Remove two operation panel unit S5 screws on the reverse side. Remove the hook lever
cover. Remove the hook cover.
Remove the cover sensor board Ass'y S5 screws. The cover sensor board ass'y screws are
tighten with the ground wire.
5. Remove the screws fixing the hook lever cover and the hook sensor board ass'y. Remove
the hook sensor board ass'y.
Fig.Part 1-40 Disassembly of Hook Sensor Board ass'y
Fig.Part 1-38 Disassembly of Panel Cover
Fig.Part 1-39 Disassembly of Hook Lever Cover
Part 1 - 88
(TP M3 × 6) × 3
(TP M3 × 6) × 1