Canon JX500 Service Manual page 75

Hide thumbs Also See for JX500:
Table of Contents

Advertisement

2) Numeric Parameter
NO.
01 OGM recording shortest time
02 OGM recording longest time
03 Waiting time until starting the OGM play
04 Number of times TAM response when TAM set is not carried out
05 Modem output level (ROM message)
06 Modem output level (RAM message)
07 Number of toll saver response (with ICM)
08 Number of toll saver response (without ICM)
09 Number of DT detection during TAM
10 Waiting time until starting the ICN recording
11 Missing number
12 T1 timer
13 T2 timer
14 T3 timer
15 T4 timer
16 Signal detection table
17 Signal detection level
18 Number of signal frequency
19
20
No.09 DT number of detection during TAM
Hungary/SAF/UK: 5
Others: 0
No.10 Waiting time until starting the ICM recording
Slovenia: 200
Others: 0
No.12 T1 timer
Canada/Taiwan/USA: 18
HK: 40
Ireland: 32
Singapore: 35
Others: 13
No.13 T2 timer
Canada/Korea/USA: 60
HK: 88
Ireland/Singapore: 80
Taiwan: 62
Others: 13
FUNCTION
Part 1 - 67
SELECTION
DEFAULT
RANGE
SETTING
0 to 9999
300
0 to 9999
2000
0 to 9999
200
0 to 9999
15
0 to 9999
14
0 to 9999
2
0 to 9999
2
0 to 9999
5
0 to 9999
5
0 to 9999
0
0 to 9999
0
0 to 9999
13
0 to 9999
63
0 to 9999
13
0 to 9999
63
0 to 9999
20
0 to 9999
4
0 to 9999
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jx300Jx200Jx201

Table of Contents