The range of selection (Numeric input):
0.1 to 19.9%
Initial value:
0.6%
Note
The LOCUT setting is not possible when ETC is set to "OFF" and DTAIL is also set to "OFF".
Measurement Range (RANGE)
(31)
Specifies the measurement range.
The range of selection (Options):
NORM / AUTO
Setting Value
NORM
AUTO
Initial value:
AUTO
Note
The table below shows the resolutions (reference values) under AUTO setting.
* The reference value indicates a typical value, not a guaranteed value.
CT rating
5A
50A
100A
200A
The measurement range cannot be specified when ETC is OFF and DTAIL is OFF.
Rate/CO
Conversion Value Setting (RATE)
(32)
2
Specifies the electricity rate or CO
The range of selection (Numeric input):
00.000 to 99.999
Initial value:
0.000
Note
The rate/CO
conversion value setting is not possible when ETC is set to "OFF".
2
(33)
Conversion Unit Setting (CONV)
Specifies the unit for the rate/CO
The range of selection (Options):
JPY (Japanese yen) / USD (US dollar) / EUR (Euro) / CNY (Chinese yuan) / KRW (Korean won) /
CO
(CO
emission level per 1kWh)
2
2
Initial value:
JPY
CTX21
The measurement range is fixed.
The measurement range is automatically switched with approximately
5% or less of the CT rated current.
Approx. more than 5%
0.1A
1.0A
2.0A
4.0A
emission level per 1kWh.
2
conversion setting (RATE).
2
4-19
3. Check and Preparation
Operation
Approx. 5% or less
0.007A
0.063A
0.125A
0.250A