Output Parameters; High Level (Hil); Low Level (Lol); Operating Characteristics - HP 8112A Operating, Programming And Servicing Manual

50 mhz programmable pulse generator
Table of Contents

Advertisement

Output Parameters

Note

High Level (HIL)

Low Level (LOL)

Operating
Characteristics
Output voltages are specified for a 50 n load. Output voltages
double when driving a high impedance load.
-7 .90 V to +8.00 V
-8.00 V to + 7 .90 V
Resolution
3 digits (10 m V)
Level accuracy
± 1 3 of programmed value ±33 of amplitude ±40 mV
Repeatability
factor 4 better than accuracy
Settling time
100 ns +LEE
Preshoot, Overshoot, Ringing
±53 ± 10 m V (variable transitions)
± 103 ±10 mV (fixed transitions)
The following sections give non-warranted information on the typical
operating characteristics of the instrument :
Trigger modes
Control modes
Output modes
Inputs and Outputs
Additional features
General characteristics
Specifications 2-3