HP 8112A Operating, Programming And Servicing Manual page 369

50 mhz programmable pulse generator
Table of Contents

Advertisement

Change 54
Main Board
Main Board
Change 55
Main Board
Note
Change 56
Main Board
Heatsink changed Q505 and Q506 a capacitor added between Q282
collector and ground to improve trigger output .
For instruments with serial number 285 1G08949 and lower, make the
following changes to the appropriate parts-list :
In Appendix A, Table A-3 modify:
Al 081 1 2-665 1 1 MP500
In Appendix A, Table A-3 delete :
Al 081 12-6651 1 C283
For instruments with serial number 285 1G08699 and lower, make the
following changes to the appropriate parts-lists:
In Appendix A, Table A-3 modify:
A l 081 12-6651 1 Q282, Q283 XSTR PNP
This change is repeated by change 46
Component value change.
For instruments with serial number 285 1G09130 and lower, make the
following changes to the appropriate parts-list :
In Appendix A, Table A-3 modify:
Al 081 12-6651 1 C501
Reference Description
Heatsink
Reference Description
Capacitor
Reference
Description
Reference Description
Capacitor
HP Part #
081 16-04151
HP Part #
0.001 µF 0160-3878
HP Part #
1853-0218
HP Part #
15 pF 0 160-4385
Backdating B-35

Hide quick links: