Display control

11.2. Display

The main display shows different inverter data:
A.
Current date, YYYY-MM-DD.
B.
Power reduction percentage and reason for this reduction*.
C.
Current time, hh:mm.
D.
Voltage and power of the PV array. Both pieces of data are displayed alternately.
E.
Power, voltage and current fed to the public grid.
F.
Wattmeter for instantaneous self-consumption. This symbol is only shown if the inverter is configured to
work in self-consumption mode. If it flashes, this is due to a communication failure with the wattmeter.
Pressing the key
takes you to the main menu. Pressing the key
displays the energy graph for the last 24 days.
* The reasons for power reduction are as follows:
T: Temperature. The inverter is limiting the power due to internal overheating.
C: Communications. The inverter is limiting the power after having received a reduction setpoint through
communications.
F: Grid frequency. The inverter is limiting the power due to the grid frequency variation.
V: Grid voltage. The inverter is limiting the power due to the grid voltage variation.
Q: Reactive priority. The inverter is limiting the power due to the injection of reactive power.
A: Configuration. The inverter is configured to limit its power.
R: Initial connection ramp. The inverter is limiting the power after a reconnection to the grid.
S: Self-consumption mode. The inverter is limiting the power due to functioning in self-consumption
mode.
M: Reserved mode.