Installation instructions
Any modifications to the device or its components are prohibited and do not
conform to its intended use.
The LPS is a protection class 1 device. Only connect the LPS to low-voltage
sources which have an earth connection (shockproof socket with PE) and a RCD
circuit breaker (FI).
Observe the following safety instructions:
Store and mount the LPS upright, never overhead or on its side.
Danger from damaged, frozen or deformed batteries: Before charging,
make sure that the battery is undamaged and the electrolyte is not frozen.
Only charge batteries in well-ventilated rooms and away from ignition
sources.
3
Technical Specifications
Model
Part number
Device
Weight
(with/without packaging)
Dimension (device)
Dimension (packaging)
Protection class
IP rating
Operating temperature
Cooling
Battery
Battery type
Available capacity
Rated value
Cycle stability at 80%
AC input
Voltage / frequency (rated
values)
Voltage range
Frequency range
Current
Charging time
Connections
LPS 1212
014-02001GF 014-01004GF 014-03001GF
26 kg / 28 kg
390 mm x 244 mm x 250 mm
495 mm x 355 mm x 350 mm
-20°C ... +50 °C
Fan, active
Lithium iron phosphate (LiFePO4)
48 Ah (634 Ah)
60 Ah (792 Ah)
2000 cycles
230 V / 50 Hz
207 V ... 253 V
45 Hz ... 65 Hz
2.5 A
95 min
Neutrik PowerCon type A
Page 3 of 25
Technical Specifications
LPS 1512
LPS 2512
28 kg / 30 kg
I
IP21
80 Ah (1056 Ah)
100 Ah (1320 Ah)
3.5 A