LEAB LPS Series User Manual page 17

Lithium power supply
Table of Contents

Advertisement

Installation instructions
Limiting Input Current (230 V, AC)
The LPS gives you the option to control the input current of the AC input,
adjustable values are between 1 A and 10 A. To limit the input current at the
AC input, perform the following steps:
Device is ready for operation.
1.
Press the OK button to access the menu.
2.
Select the menu item '230VAC Charging' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
3.
Select the menu item 'Maximum Current' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
4.
Select the desired current limit value by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
5.
To exit the menu, press the left arrow button twice.
The input current is limited.
Activate/Deactivate 230-V Output
To activated or deactivate the 230-V output, perform the following steps:
Device is ready for operation.
1.
Press the On/Off button to open the On/Off menu.
2.
Select the menu item 'AC Out' by pressing the arrow buttons (up/down).
The following icons are displayed:
AC output is active
Mains priority circuit is active
AC output is inactive
3.
To change the setting, press the OK button.
4.
To exit the On/Off menu, press the left arrow button.
The 230-V output is activated or deactivated.