Installation instructions
Limiting Input Current (230 V, AC)
The LPS gives you the option to control the input current of the AC input,
adjustable values are between 1 A and 10 A. To limit the input current at the
AC input, perform the following steps:
Device is ready for operation.
1.
Press the OK button to access the menu.
2.
Select the menu item '230VAC Charging' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
3.
Select the menu item 'Maximum Current' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
4.
Select the desired current limit value by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
5.
To exit the menu, press the left arrow button twice.
The input current is limited.
Activate/Deactivate 230-V Output
To activated or deactivate the 230-V output, perform the following steps:
Device is ready for operation.
1.
Press the On/Off button to open the On/Off menu.
2.
Select the menu item 'AC Out' by pressing the arrow buttons (up/down).
The following icons are displayed:
AC output is active
Mains priority circuit is active
AC output is inactive
3.
To change the setting, press the OK button.
4.
To exit the On/Off menu, press the left arrow button.
The 230-V output is activated or deactivated.
Page 16 of 25
Operation