Installation instructions
Deactivate/Activate Energy Saver (230 V, DC)
The Energy Saver is used to set a threshold and a time. If the value falls below
this threshold, the set time runs down and the AC output (230 V) is
automatically deactivated after the time has elapsed.
To activated or deactivate the Energy Saver, perform the following steps:
The device is switched on.
1.
Press the OK button to access the menu.
2.
Select the menu item '230VAC Output' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
3.
Select the menu item 'Energy Saver (Threshold)' by pressing the arrow
buttons (up/down) and confirm selection by pressing the OK button.
4.
In order to activate the Energy Saver, select a value between 0 W and
200 W by pressing the arrow buttons (up/down) and confirm selection by
pressing the OK button.
5.
To exit the menu, press the left arrow button.
6.
Select the menu item 'Energy Saver (No Load)' by pressing the arrow
buttons (up/down) and confirm selection by pressing the OK button.
7.
In order to activate the Energy Saver, select a time between 1 min ... 10 h
by pressing the arrow buttons (up/down) and confirm selection by
pressing the OK button.
8.
To deactivate the Energy Saver, press the down arrow button until
'inactive' is displayed and confirm the selection with the OK button.
9.
To exit the menu, press the left arrow button twice.
The Energy Saver is activated or deactivated.
Charging the LPS (12 V, DC)
The LPS is automatically charged with 12 V when a voltage is applied to the
DC input and a signal is applied to the D-Sub connector.
If there is no signal at the D-Sub connector or no voltage, the LPS is
not charged.
Page 17 of 25