Installation - LEAB LPS Series User Manual

Lithium power supply
Table of Contents

Advertisement

Installation instructions

10 Installation

Ensure that the LPS is switched off during installation.
Connecting the AC Input (230 V)
To install the device to the 230-V mains, perform the following steps:
1.
Insert the blue Neutrik plug of the mains cable into the AC input (230 V)
on the device.
2.
Turn the Neutrik plug clockwise until it clicks into place.
3.
Plug the two-pin earthed plug into a 230-V mains supply.
The LPS starts the charging process automatically, consumers at the
AC output (230 V) are supplied with power via the 230-V mains
(mains priority circuit).
The device is connected.
Connecting the DC Input (12 V)
To connect the LPS to the vehicle battery, perform the following steps:
Grey Anderson plug is mounted.
1.
Disconnect the battery from the vehicle power circuit.
Warning: Disconnect the negative cable first.
2.
Secure the positive cable of the grey Anderson plug as close as possible to
the vehicle battery with a suitable fuse (80 A).
3.
Connect the positive cable of the grey Anderson plug with the positive
terminal of the battery.
4.
Connect the negative cable of the grey Anderson plug to the negative
terminal of the battery.
5.
Connect a signal cable (1 mm²) to terminal 15 (switched ignition plus) or
terminal 61 (ignition signal) of the vehicle.
Page 11 of 25