Installation instructions
Activate/Deactivate 12-V Output
To activated or deactivate the 12-V output, perform the following steps:
Device is ready for operation.
1.
Press the On/Off button to open the On/Off menu.
2.
Select the menu item 'DC Out' by pressing the arrow buttons (up/down).
DC output is active
DC output is inactive
3.
To change the setting, press the OK button.
4.
To exit the menu, press the left arrow button.
The 12-V output is activated or deactivated.
Activate Jumpstart Function (Emergency Start) (12 V, DC)
With the help of the jumpstart function (emergency start), a discharged starter
battery can be jumpstarted by the LPS to such an extent that a starting process
is possible again.
To activate the jumpstart function, perform the following steps:
The device is switched on.
A CDR was installed (before HW version 12.20/15.20/25.20 , s.
page 14)
1.
Press the OK button to access the menu.
2.
Select the menu item '12VDC Output' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
3.
Select the menu item 'Jumpstart' by pressing the arrow buttons
(up/down) and confirm selection by pressing the OK button.
4.
To activate the jumpstart function, press the OK button.
A charging current of 40 A is provided for 5 min at the DC input.
After 5 minutes, the vehicle can be started as usual.
5.
To exit the menu, press the left arrow button twice.
The jumpstart function is activated.