Installation instructions
Mounting the D-Sub Data Adapter
To mount the D-Sub data adapter, observe the following instructions:
You need an H07V-K or equivalent electrical cable with a
cross-section of 1 mm² and, if necessary, a fuse holder.
Pin
1
2
3
4
5
6
7
8
9
* From hardware 2.02 (up to hardware 2.01: GND (ground))
** can be parametrised accordingly
*** Allocation necessary for installation at DC input
9
Mounting
To mount the device, perform the following steps:
NOTICE
Choose a cool, dry and well-ventilated mounting site.
Mount the device on a flat surface.
Do not mount the device directly next to or above batteries or any
flammable materials
1.
Fasten the device to the mounting location with screws on the underside
of the device or with the LPS mounting plate (optional accessory).
The device is mounted.
Item
Use
Single wire
Data transmission
CAN-Low
Software update
GND
Ground connection for
accessories
+12 V*
+12 V (active, if LPS active)
Input 2
External switching signal
(switching the inverter)
Output 1
CDR connection (jumpstart
function)
CAN-High
Software update
Output 2
Signal output**
Input 1
Activation of DC input after 10 s
connection D+ signal (terminal
15/terminal 61)***
Page 10 of 25
Mounting