Ambient Conditions; Used Standards - Bosch Rexroth IndraControl VPP 21.2 Project Planning Manual

Table of Contents

Advertisement

18/65
Bosch Rexroth AG | Electric Drives
Technical Data
4.4

Ambient Conditions

In operation
Ambient temperature
+5 ... +45 °C
(surrounding air tempera‐
For operation of the housing ventilator refer to
ture)
"Pin 3 and Pin 4: Fan Supply" on page 50
Max. temperature gradi‐
Temporal temperature changes up to 3 °C per minute
ent
Relative humidity
Climatic class 3K3 according to EN 60721, non-con‐
densing. 80 % humidity max. for 25 °C
Air pressure
Up to 2,187.23 yd above MSL according to DIN 60204 Up to 3,280.84 yd above MSL according
Mechanical strength
Max. vibration: Frequency range: 10 ... 150 Hz
Excursion: 0.075 mm at 10 ... 57 Hz
Acceleration: 1 g at 57...150 Hz
Test duration for each axis: 10 frequency cycles
Frequency sweep rate: 1 octaver/min
According to EN 60068-2-6, test Fc
4.5

Used Standards

and Controls
Interfaces
Additional interface via a
Hilscher COM module
Slots for connector panel
Slot
Fig.4-3:
Technical data PC
Fig.4-4:
Ambient Conditions
A slot for a 2.5" hard disk is integrated in the connector panel of the
VPP 21 box. If you use a hard disk, which is not suitable for the
ambient conditions mentioned in the
tions" on page
by the hard disk manufacturer for the VPP 21.
The system components of the VPP 21.2 correspond to the following standards:
Rexroth IndraControl VPP 21.2 | Project Planning Manual
1 x external VGA connection (15-pin, HD-Sub)
2 x Ethernet connection (RJ 45, 10/100 Base-T)
1 x USB interface
1 x serial standard interface
1 x keyboard connection (PS/2)
1 x mouse connection (PS/2)
2 x 24 V outputs
Profibus DP Master/Slave
1 x slot for Compact Flash Card
1 x slot for 2.5" hard disk
1 x PCI slot for short cards
Storage / Transport
-20 °C to +60 °C
chapter
Temporal temperature changes up to 3 °
C per minute
Climatic class 3K3 according to
EN 60721, non-condensing. 80 % hu‐
midity max. for 25 °C
to DIN 60204
Max. shock: 15 g according to EN 60
068-2-27, no disturbance of the function
18, you must ensure the ambient conditions required
chapter 4.4 "Ambient Condi‐

Advertisement