Plunger
Before applying to the quick disconnect, use the
plunger to evenly push out a small amount of resin to
get a proper mix of of the 2-part epoxy. Then apply
resin into the housing, enough to cover the wires and
contacts. The resin should be about 3mm onto the
cord jacket. Note: Adding too much resin may cause
excess to be forced into the female end of the pin
connector, preventing proper connection of the two
halves.
STEP SIX
Slide the gland and gland nut along the cable into the
body and tighten the gland nut securely. No drying
time is needed for the epoxy before full assembly.
STEP SEVEN
Once the two subassemblies have been completed,
they can be joined together. Plug pin assembly into
the socket assembly and tighten the large blue nut
securely. The blue nut should be hand tightened only.
(See fi gure below).
Note: There is a small gap after tightening
For sea-
al removal, your quick disconnect includes an optional
water tight cover. Simply separate the quick discon-
4
Resin Tube
Nozzle
Cut-Away
disconnect shown
with clear resin.
Note amount that
is covering cord
son-
nect and insert the sealing cover into the large blue nut
half and tighten fi rmly.
Strain Relief
The Strain Relief must be installed to protect the
Quick Disconnect from damage due to excessive
strain. The Strain Relief should be installed on the
user supplied cord length (not on the Kasco supplied
stub cord). It should be position about 15cm from the
Quick Disconnect. To install, insert the narrow end of
the elongated clamp with the chain connected into the
wide end of the short clamp. Use a rubber mallet to
tap the two pieces together securely. A Nylon Tie can
be used to keep it attached to the cord. The chain can
then be attached to the fl oat.
Wire Sizing & Gland Sizing
The chart below shows the proper Gland to be used
with different cord sizes. The measurements are based
on the Outside Diameter (O.D.) of the cord. Smooth,
round cords should be used. (HAR H07RN-F)
Kasco Quick Disconnect 50 Hz Size Chart:
Gland
Grey
White
Black
Yellow
Kasco 50 Hz Equipment Wire Size Chart
Model
10m
2
8400EJ
1.5mm
2
3.1EVX
1.5mm
2
3.1EJ
1.5mm
2
2.3EJ
2.5mm
O.D. of Cord
7-9mm
9-11mm
11-13mm
13-15mm
Cord Length
30m
60m
90m
2
2
2.5mm
4mm
6mm
2
2
2.5mm
6mm
6mm
2
2
2.5mm
6mm
6mm
2
2
2.5mm
2.5mm
4mm
2
2
2
2