PRE-INSTALLATION ASSEMBLY
Brass Pipe
Fitting
Assembly of pressure control module to pump
Some models are despatched with the pressure control module detached from the
pump. To assemble, the brass pipe fitting attached to the control module must be inserted
into the pump outlet connector (Fig. 2). The control module and pipe fitting must be
pushed firmly down into the outlet connector a distance of 35 mm, until the end stop
resistance is felt (Fig. 3).

SITING OF THE PUMP/PIPEWORK

WARNINGS:
Pump Location
If possible site the pump in a location where in the unlikely event of a
liquid leak, any spillage is contained or routed to avoid electrics or
areas sensitive to liquid damage.
Care should be taken to protect pump from frost and freezing.
Ensure pipework to and from pump is independently supported to
prevent forces being transferred to inlet and outlet branches of pump.
Do not introduce solder flux to pumps or pump parts manufactured
from plastics. All solder joints should be completed and flux residues
removed prior to pump connection.
Do not allow plastic pump parts to come into contact with oil or
cellulose based paints, paint thinners or strippers, acid based
descalents or aggressive cleaning agents.
The motor casing can become very hot under normal operating
conditions, care should be taken to ensure it cannot be touched during
operation.
Pressure Control
Module
Pump Outlet
Connector
Fig. 2
(Surface Models)
-6-
Fig. 3

Advertisement