If the power cord is to be extended, a cord of the same specification should be used. If
the installation is outdoors then any connectors or junction boxes must be specifically
suited for outdoor use and installed in accordance with the manufacturers instructions.
Any cable routed underground must be protected to local standards.
Intermediate Connecting Cord Extension (Models Diver 3 and 4)
The intermediate connecting cord which connects the pump to the control module is of
a type suitable for outdoor use. Cord specification is as follows:
H07RN-F3 G 1.0 mm² - 10 amp rating.
If an extension cord is necessary a cord of the proper type and rating must be used.
In general for 230 volt pumps on distances up to 40 metres (inclusive of original cord
length) the same specification cord as fitted to the pump can be used. For distances
above 40 metres a larger cord size may be required due to voltage drop and advice must
be obtained based upon installation details.
Any connectors or junction boxes must be specifically suited for outdoor use and
installed in accordance with manufacturers instructions.
Any cable routed underground must be protected to local standards.

NOISE

The equivalent continuous A-weighted sound pressure level at a distance of 1 metre
from the pumpset does not exceed

COMMISSIONING

WARNINGS:
The motor casing can become very hot under normal operating
conditions, care should be taken to ensure it cannot be touched during
operation.
Do not run pump without guards and terminal box lids correctly fitted.
Care should be taken to protect the pump from freezing.
The pump chamber must be full of liquid at all times. Seal damage will
result if the pump runs dry.
1. System Flushing
This pump-set incorporates push-in connectors and plastic components that
must not come into contact with solder flux, acid-based descalents or
aggressive cleaning agents. The pipework system should be flushed out
prior to the pump being connected to ensure any contaminants/chemical
residues and foreign bodies are removed from elsewhere in the system.
2. Liquid Supply
Always ensure that liquid storage capacity is adequate to meet the demand.
Ensure the pump chamber is full of liquid before starting the pump. Failure
to do this could result in seal damage. To ensure dry running does not
occur the pumps must be primed as described in priming section. Do not
run pump dry.
70 dB(A) for all models except Jet range.
76 dB(A) for Jet 40
81 dB(A) for Jet 90