Sensor Settings - HDL Buspro -MSM.431 User Manual

Advanced security controller
Table of Contents

Advertisement

User Manual
SB-DN-SEC250K
c) Configure button 2 to disarm, parameter2 is 'disarm', other settings are same as
button 1.

6.2 Sensor Settings

a) Go to 8in1's Security Function page, enable the security function of dry contact 1, dry
contact 2 and IR sensor. Input the security module's ID, here is 1/3, and select area 1.
b) Go to security module's Bypass Settings page, enable the alarm for index 1/2/3, input
the 8in1 sensor's ID, here is 1/77, and channel 1/2/3(the index No. in 8in1 sensor). Close
the doors, and make sure there is no movement in the detection range of 8in1, then
refresh this page, you will be able to get the normal status of these three channels in the
'Status' column, here channel1, channel2 and channel 3 status are 'Close', then select
'NC' for them in 'Trigger' column(if it shows 'OFF' under normal situation, then select 'NO'
for it)
Advanced Security Controller – User Manual