5.2 Basic Setting

It's mainly for buzzer and siren configuration.
Area No.
Select and enable one area(area No. is from 1 to 8), remark it for easy management, like
floor1 or floor2.
Siren Delay(10-180S)
Set the delay time for INDOOR SIREN ON, OUTDOOR SIREN ON
Restart after Alarm(1-30M)
Once alarm is triggered, within the delay time (up to 30 minutes), the security module will
no longer alarm again. When the delay time elapses, it will restart into the monitoring state,
if there are more triggers, it will trigger the buzzer, siren, alarm and so on then realize that
monitor and alarm circularly.
Entry Delay(10-180S)
The delay time for entering the door. Under arming, it will trigger the "ENTER BUZZER
ON" targets when entry. If disarmed during the delay time, the "ENTER BUZZER OFF"
targets will be triggered.
TIP: If do not disarm after the Entry Delay, it will trigger the "ALARM BUZZER ON" setting
targets, at the same time, start to countdown the Siren Delay time, when the delay time
elapses, the system will trigger "INDOOR SIREN ON, OUTDOOR SIREN ON" setting
targets.
Advanced Security Controller – User Manual
7