HDL Buspro -MSM.431 User Manual page 12

Advanced security controller
Table of Contents

Advertisement

User Manual
SB-DN-SEC250K
UV Switch No. 1-4 is for Mode One to Mode Four in area1, Switch No. 5-8 is for Mode
One to Mode Four in area2 and so on. Default is for normal weather, if it does not receive
any UV Switch No. from the sensor, then it will trigger the setting targets in Default window.
Mode One to Mode Four is for abnormal weather, when it receives one UV Switch No.
from the sensor, it will trigger corresponding targets.
E.g. Mode One is for rainy day, when the sensor detects it's raining now, it will send UV
Switch 1 to the security module, then security module will trigger the Z-Audio to play the
st
21
voice hint, the voice hint can be 'it's raining outside, do not forget to take the umbrella
with you'.
It will trigger the Beep Tone targets firstly, later trigger the EXIT BUZZER ON targets when
leaving the house.
EXIT BUZZER ON
The actions when leaving the house, the targets can be a voice hint from music player or a
buzzer on controlled by relay module.
EXIT BUZZER 5S LEFT
The actions for the last 5 seconds of exit delay, the targets can be a rapid buzzer on, to
urge people to leave the house quickly.
EXIT BUZZER OFF
Automatically shut down the voice hint and buzzer when the Exit Delay time elapses.
When disarmed, it will trigger the 'EXIT BUZZER OFF' targets.
ALARM BUZZER ON
If there is no disarm after Entry Delay, it will trigger the 'ALARM BUZZER ON' targets and
the 'ENTER BUZZER OFF' targets at the same time.
Advanced Security Controller – User Manual
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Buspro sb-dn-sec250k