Transport And Storage - MSA Vautex Elite S Operating Manual

Chemical protective suit type 1a en 943 - 1:2002
Hide thumbs Also See for Vautex Elite S:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
MSA
Reassembling the safety high boots
Attention!
In order to guarantee full tightness, check the tightness of the suit ( Section 5.2)
after each replacement of the safety high boots before the cap tube is fitted over the
shaft of the boot.
(1) Push safety high boot into the suit leg that was turned inside out.
(2) Align suit leg and boot.
(3) Insert tube piece in the boot shaft.
(4) Fit the screw and nut clamp on.
(5) Turn clamp lock towards the rear.
(6) Fit clamp protector under clamp.
(7) Tighten screw and nut clamp with SW7, tightening torque: 500 ±30 Ncm.
(8) Clamp protection must cover the clamp lock.
(9) Push safety high boot to the outside.
(10) After tightness test, fit cap tube over shaft of boot.
6.

Transport and Storage

Attention!
When storing the protective suit on vehicles or containers abrasion through
permanent friction with the contact surface has to be avoided.
Attention!
In order to prevent damage to the protective suit, the material, seams, and zip must
not be forcibly kinked or folded!
The zip should remain closed during storage.
The suit can, for example, be loosely folded as a large package.
The protective suit is supplied folded and pressure-free. Storage must be in a loosely folded
pack in clean and dry conditions in a normal atmosphere free from toxic substances, protected
from direct sunlight and temperature changes (according to DIN 7716 and ISO 2230).
The operational life can change as a result of environmental influences, such as UV light, heat,
humidity. The storage room must be cool, dry, dust-free and well ventilated.
The storage temperature is between -5 °C and +25 °C. The optimum storage temperature is
between +15°C and +25°C, since in the long-term there could otherwise be a change in the
physical properties or a shortening of the service life.
The relative air humidity is best at under 65%.
GB
Vautex Elite S
TRANSPORT AND STORAGE
21