MAINTENANCE

4.2.

Disinfection

Disinfection should only be carried out as follows using disinfectant AUER 90 only:
(1) Dilute the disinfectant AUER 90 with water (water temperature max. 30°C).
(2) Immerse the parts to be disinfected directly in the disinfectant solution or apply the solution
with a rag and allow it to work.
(3) Then rinse all parts thoroughly with water.
Concentration and working times of the disinfectant AUER 90:
Normal disinfection
Attention!
The safety instructions on the bottle or container of the disinfectant AUER 90 must be
observed.
5.
Maintenance
5.1.

Maintenance Intervals

The maintenance work shall be carried out by qualified service engineers or technicians. The
corresponding seminars can be ordered at MSA.
All maintenance work carried out must be noted on the appropriate inspection plate.
The maintenance periods specified below refer only to protective suits.
Task to be Performed
Cleaning, Disinfection
Maintenance
Function test and tightness test
Valve disc replacement
Sealing ring replacement
Control by wearer
Service zip
14
Concentration
2.0%
Before Use
After Use
X
X
X
X
X
X
Vautex Elite S
MSA
Working Time
15 Minutes
Half-Yearly
Every Two
Years
X
X
X
X
X
GB