19.4.14 Setting the Edge guide parameters

Various settings can be made for the edge guide (motor driven).
The possibilities are explained in more detail in the table
Icon
144
NOTICE
Property damage may occur!
Sewing feet, needle, edge guide and sewing equipment can be
damaged.
ALWAYS check the distance to the edge guide and input the correct
value after changing the sewing equipment.
Menu items
Edge guide
Edge Guide Mode
Motor driven
Speed
Travel speed of the edge guide
Value range
• Value range
On/Off
• Value range
1-axis Internal/
1-axis External/
2-axis External
Internal: the stepper
motor card of the edge
guide is housed inside
the control
External: the stepper
motor card of the edge
guide is located on the
component
• Value range
On/Off
• Value range
0500 - 60000 [Hz]