1007
1008
1010
1011
1012
1054
1055
1060
1061
1120
1121
1203
1302
1330
2101
2105
2121
2122
208
Code
Type
Meaning
Error
Error in the reference run
Error
Sewing motor encoder error
Error
External synchronizer plug
(Sub-D, 9-pin) not connected
Error
Encoder Z pulse missing
Error
Synchronizer fault
Error
Internal short circuit
Error
Sewing motor overload
Error
Sewing motor overload / overvoltage /
overcurrent
Error
Sewing motor overload / overvoltage /
overcurrent
Error
Sewing motor Init fault
Error
Sewing motor watchdog
Error
Position not reached (during thread
cutting, reversal, etc.)
Error
Failure with sewing motor current
Error
No response from sewing motor
Error
Stepper motor X30 reference run
timeout
Error
Stepper motor card X30 blockage
Error
Stepper motor card X30 encoder plug
(Sub-D, 9-pin) not connected
Error
Stepper motor card X30 flywheel
position not found
Remedial action
• Replace encoder
• Check for stiff movement
• Replace encoder
• Connect cable of external
synchronizer to control, make sure
that interface (Sync) is correct
• Only recommended for machines
with transmission!
• Switch off the control, use
handwheel to turn, and switch on
the control again
• If error is not corrected, check
encoder
• Replace synchronizer
• Replace control
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
• Perform a software update
• Check selection of class
• Perform a software update
• Check selection of class
• Check the controller settings and
change them if necessary
(e.g. thread trimmer setting, belt
tension, etc.)
• Check position thread lever at top
dead center
• Check Service Stop
• Check for stiff movement
• Replace encoder
• Replace motor
• Perform a software update
• Replace control
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the
control, use the correct interface
• Check stepper motor 1 for stiff
movement