Canon MX860 Service Manual page 19

Hide thumbs Also See for MX860:
Table of Contents

Advertisement

##762
TX
After transmitting PPS-EOM in ECM transmission, DCN has
been received.
##763
TX
After transmitting PPS-EOM in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60
sec.) has occurred.
##764
TX
After transmitting PPS-EOM in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
##765
TX
After transmitting PPS-EOP in ECM transmission, no
significant signal has been received, and re-transmission of
the procedure signal has been attempted the number of
specified times but failed.
##767
TX
After transmitting PPS-EOP in ECM transmission, DCN has
been received.
##768
TX
After transmitting PPS-EOP in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60
sec.) has occurred.
##769
TX
After transmitting PPS-EOP in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
##770
TX
After transmitting EOR-NULL in ECM transmission, no
significant signal has been received, and re-transmission of
the procedure signal has been attempted the number of
specified times but failed.
##772
TX
After transmitting EOR-NULL in ECM transmission, DCN
has been received.
##773
TX
After transmitting EOR-NULL in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60
sec.) has occurred.
##774
TX
After transmitting EOR-NULL in ECM transmission, ERR
has been received.
##775
TX
After transmitting EOR-MPS in ECM transmission, no
significant signal has been received, and re-transmission of
the procedure signal has been attempted the number of
specified times but failed.
##777
TX
After transmitting EOR-MPS in ECM transmission, DCN has
been received.
##778
TX
After transmitting EOR-MPS in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60
sec.) has occurred.
##779
TX
After transmitting EOR-MPS in ECM transmission, ERR has
been received.
##780
TX
After transmitting EOR-EOM in ECM transmission, no
significant signal has been received, and re-transmission of
the procedure signal has been attempted the number of
specified times but failed.
##782
TX
After transmitting EOR-EOM in ECM transmission, DCN
16 / 64
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Increase the transmission level of the

Advertisement