HMI LCD display type AS

Change from one to two columns
6
HMI LCD display type AS
Change from one to two columns
6.1
Ex relevant specifications
6.1.1
Intrinsic Safety ATEX
Explosion protection
Approved for use in Zone 0.
Designation
II 1G Ex ia IIC T6
EC type-examination certificate PTB 05 ATEX 2079 X
6.1.2
Intrinsic Safety IECEx
Explosion protection
Approved for use in Zone 0.
Designation
Ex ia IIC T6
For further information, see certificate
6.1.3
Safety specifications for Intrinsic Safety
ATEX / IECEx
Temperature table
Temperature
Permissible ambient temperature range
class
Device category 1
use
T6
-40 ... 44 °C
(-40 ... 111.2 °F)
T5
-40 ... 56 °C
(-40 ... 132.8 °F)
T4
-40 ... 60 °C
(-40 ... 140 °F)
Protection type intrinsic safety Ex ia IIC
Supply circuit
Max. voltage
U
= 9 V
i
Short circuit current
I
= 65.2 mA
i
Max. power
P
= 101 W
i
Internal inductance
L
= 0 mH
i
Internal
C
= 0 nF
i
capacitance
Change from one to two columns
20 - EN
6.1.4
6.1.5
6.1.6
Device category 2
use
-40 ... 56 °C
6.1.7
(-40 ... 132.8 °F)
-40 ... 71 °C
(-40 ... 159.8 °F)
-40 ... 85 °C
(-40 ... 185 °F)
TTH200
Intrinsically Safe FM
I.S. Class I Div 1 and Div 2, Group: A, B, C, D or
I.S. Class I Zone 0 AEx ia IIC T*
Temp. Ident: T6 T
56 °C, T4 T
amb
U
/ V
= 9V, I
/ I
< 65,2 mA, P
i
max
i
max
C
= 0,4 µF; L
= 0
i
i
Control Drawing: SAP_214 748
Non-Incendive FM
N.I. Class I Div 2, Group: A, B, C, D or
Ex nL IIC T*, Class I Zone 2
Temp. Ident: T6 T
60 °C, T4 T
amb
U
/ V
= 9V, I
/ I
< 65,2 mA, P
i
max
i
max
C
= 0,4 µF; L
= 0
i
i
Control Drawing: SAP_214 751
Intrinsically Safe CSA
I.S. Class I Div 1 and Div 2; Group: A, B, C, D or
I.S Zone 0 Ex ia IIC T*
*Temp. Ident T6 T
56 C, T4 T
amb
U
/ V
= 9V, I
/ I
< 65,2 mA; P
i
max
i
max
C
< 0,4 F
, L
= 0
i
µ
i
Control Drawing: SAP_214 799
Non-Incendive CSA
N.I. Class I Div 2, Group: A, B, C, D or
Ex nL IIC T*, Class I Zone 2
*Temp. Ident T6, T
60 °C, T4 T
amb
U
/ V
= 9V, I
/ I
< 65,2 mA, P
i
max
i
max
C
< 0,4 µF, L
= 0
i
i
Control Drawing: SAP_214 750
85 °C
amb
= 101 mW
i
85 °C
amb
= 101 mW
i
85 °C
amb
= 101 mW
i
85 °C
amb
= 101 mW
i