Mounting

3
Mounting
3.1

Installation options

There are three options for mounting the transmitter in the temperature sensor heads:
in the cover of the connection head (without springs)
directly on the measuring inset (spring mounted)
on a top hat rail
3.1.1

Installation in the cover of the connection head

Fig. 2
1. Release the screw plug (3) for the cover of the connection head.
2. Open the cover (1).
3. Secure the transmitter (2) at the proper position on the cover, using the captive screws found
in the transmitter.
10 - EN
TTH200
1
2
3
A00067
CI/TTH200-EN