7

RECO PLC MTS-R01.2

7.1

Brief Description

X10 Programming interface (PROG)
RS232/RS422/RS485
X1 Voltage supply and
+24 VDC
0V
free
free
SPS READY
X15 BT BUS for connecting
DOK-CONTRL-MTS-R0*.2G2-PR01-EN-P
The MTS-R01.2 is an efficient PLC in small-size format and in IP 20 de-
sign. It requires 1 slot in the RMB02.2 module carrier and can be used as
a stand alone PLC with the corresponding I/Os or together with motion
control as a combined CNC-PLC system. Operating devices, e.g.
BTM15/16 or BTA20, must be connected to the MTS-R01.2 using the BT
bus. The optional slot U1 can be used to fit components on open field bus
interfaces, such as INTERBUS, PROFIBUS DP or DeviceNet.
System no.: 0 - 15
d
(e.g. 07)
Watchdog: SPC Ready
1
+24V
2
GND
3
NC
4
NC
5
WD
6
WD
up to 4 operating devices

Fig. 7-1: MTS-R01.2

RECO
8
H1
H1 Status indicator
X60
0 7
0 7
IBS-
U1 Optional slot
MASTER
DEVICE-NO
X10
e.g. INTERBUS module
X64
U1
PROG
RESET
X16
X1
+24V
1
0V
2
X16 Serial interface (COM)
3
NC
NC
4
RS232/RS422/RS485
5
WD
6
COM
MTS-R01.2
Grounding bolt
Diagnosis connector
(For Service only
OFF
O P E N
Default setting
1 2 3 4 5 6 7 8
ON
MTS-R01_Kurz.FH7
RECO PLC MTS-R01.2
7-1