IMPORTANT PARTS OF YOUR CONCENTRATOR

Please take time to familiarize yourself with your DeVilbiss oxygen concentrator before operating .
1
2
A
6
Front View (Figure A)
1 .
Operating instructions
2 .
Power Switch
| = ON
O = OFF
3 .
Flow meter knob
4.
Flow meter
5.
Circuit breaker – resets the unit after electrical overload shutdown
6.
Oxygen outlet – oxygen is dispersed through this port
7.
Normal Oxygen (green) light (see page 8)
8.
Low Oxygen (yellow) light (see page 8)
9.
Red Service Required (red) light – when illuminated contact your DeVilbiss
provider
10 . Hour meter
Accessories
Transfiller Caddy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DeVilbiss 525DD-650
Bubble Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Salter Labs 7600 or equivalent
There are many types of humidifiers, oxygen tubing and cannulas/masks that can be used with this device. Certain humidifiers and accessories may impair the device's
performance. A mask or any nasal cannula can be used with continuous flow delivery and may be sized according to your prescription as recommended by your homecare
provider who should also give you advice on the proper usage, maintenance and cleaning .
WARNING
When using the Transfiller Caddy with a Transfill device, always keep the system on a flat surface. Disassemble the system prior to moving.
NOTE – The bubble humidifier should be supplied with a permanent fire stop device. If a bubble humidifier needs to be used without a permanent fire stop device, a
secondary fire stop device must be used and placed as close to the humidifier as possible. Failing to do so could increase the risk of fire. Country Standards may vary. Please
contact your provider for information.
NOTE – A maximum of 50 feet (15 meters) of crush-proof oxygen tubing, plus 7 feet (2.1 meters) of cannula, plus a bubble humidifier is allowed between the concentrator
and the patient.
NOTE – The oxygen supply accessory (patient tubing) shall be equipped with a means that, in case of fire, stops the delivery of
oxygen to the patient. This means of protection should be located as close to the patient as practicable. Country Standards may
vary. Please contact your provider for information.
NOTE – Your healthcare provider should verify the compatibility of the oxygen concentrator and all of the parts used to connect to the patient before use.
EN - 6
8
7
9
3
4
5
10
B
15
16
11
14
12
13
Back View (Figure B)
11 . Handgrip
12 . Exhaust
CAUTION
When device is used under extreme operating conditions, the
temperature near the exhaust vents on the bottom of the unit may
reach 145˚F (63˚C). Keep body parts a minimum of 32" (81.2 cm) away
from this area .
13 . Power cord and/or IEC power connector .
14. Line cord strap
15. Air filter – prevents dirt, dust and lint from entering your unit.
16. Auxiliary Oxygen Port (Serial numbers starting with R, N, or B): Your
concentrator is equipped with an auxiliary oxygen port that can be used to fill
oxygen cylinders with an FDA-cleared cylinder filling device that is designed
to use oxygen from a concentrator to fill a cylinder. The port is only for use
with FDA-cleared filling devices with compatible oxygen input specifications.
Refer to the cylinder filling device instruction guide for the oxygen input/
output specifications, connection and operating instructions.
11
12
SE-525K4