Display
Cause
"E-10"
High limit.
"E-15"
Drain switch.
"E-18A"
Left level sensor
open.
"E-18B"
Right level sen-
sor open.
"E-18C"
Both level sen-
sors open.
"E-21"
Slow heat
recovery.
"E-22"
Elements not
"NO HEAT"
heating.
"CHECK
PWR
CORD
AND
BREAKER"
"E-31"
Elements are up.
"E-41"
Programming
"E-46"
failure.
"E-47"
Analog converter
chip or 12-volt
supply failure.
"E-48"
Input system
error.
"E-54C"
Temperature in-
put error.
Panel Board Correction
Let the unit cool down (15-20 minutes), insert the high limit
tool, on the inside of the LH door, gently into the hole in
the heating element hinge. If the high limit does not reset,
high limit must be replaced.
Make sure drain knob is completely pushed-in; if E-15 per-
sists, have drain switch checked.
Turn switch to off position, then back to on; if display still
indicates a failed sensor, have the connections checked
on the control board. Have sensor check and replaced if
necessary.
Have a certified service technician check the fryer for cor-
rect voltage to the unit; have heat circuit checked; have
unit checked for loose or burnt wires.
Have power cord and heat circuit checked.
Lower elements completely back into the vat.
Turn power switch to off, then back to on; if display shows
an error code, have the controls re-initialized; if error code
persists, have the control board replaced.
Turn power switch off, then back to on; if "E-47" persists,
have the I/O board, or the PC board replaced; if speaker
tones are quiet, probably I/O board failure; have the I/O
board replaced.
Have PC board replaced.
Turn power switch to off, then back to on; have control PC
board replaced if "E-54C" persists.