Menu Step
SP-26 Usage Code
Change
SP-27 Dispose Re-
quires Code?
SP-28 Longer Fill
Time
SP-29 Let User Exit
Fill
SP-30 Skip "SKIM"
Prompt
SP-31 2-Stage
Wash Enabled
6 6 . . 2 2 D D o o N N o o t t D D i i s s t t u u r r b b
Time periods of peak operations during which the "FILTER NOW?" message will not
appear, may be programmed into the fryer. There are three groupings of days -
Monday thru Friday (M-F), Saturday (SAT), and Sunday (SUN). Within each day
grouping, up to 4 time periods (M-F 1 thru M-F 4, SAT 1 thru SAT 4, and SUN 1 thru
SUN 4) may be programmed. A time period may be anywhere from 1 to 180 minutes
in length.
Press and hold the program button for 5 seconds until "LEVEL 2" "SP PROG"
1 1 ) )
"ENTER CODE" shows in the display.
66
back to "SP-25" "CHANGE MGR CODE? 1=YES". Now the above
steps can be repeated.
This allows the operator to change the reset usage code (factory set
at 1, 2, 3) to reset the usage amounts of each product. See
view Usage , page 52
in Information Mode. Press and release the right
arrow button until "SP-26 CHANGE USAGE CODE? 1=YES" flashes
in the display. Press product button 1 and "ENTER NEW CODE, P=
DONE, I-QUIT" scrolls through display. Press product buttons for new
code. If satisfied with code, press the program button and "REPEAT
NEW CODE, P=DONE, I=QUIT" shows in the display. Enter the pre-
viously entered code. If satisfied with code, press the program button,
"*CODE CHANGED*" shows in display. If not satisfied with code,
press the info button and "*CANCEL*" shows in display the reverts
back to "SP-26" "CHANGE USAGE CODE? 1=YES". Now the above
steps can be repeated.
Press and release the right arrow button and "SP-27 DISPOSE RE-
QUIRES CODE?" flashes in the left display. Press the up and down
arrow buttons to choose "YES" or "NO". If set to "YES", code 1, 2, 3,
must be entered to discard the oil from the vat using the Dispose
Mode.
Press and release the right arrow button until "SP-28 LONGER FILL
TIME ENABLED?" flashes in the left display. Press the up and down
buttons to choose "YES" or "NO".
Press and release the right arrow button until "SP-29 LET USER EXIT
FILL" flashes in the left display. Press the up and down arrow buttons
to choose "YES" or "NO". If "YES" is chosen, the user can exit the Ex-
press Filter™ fill operation.
Press and release the right arrow button until "SP-30 SKIP 'SKIM'
PROMPT?" flashes in the left display. Press the up and down arrow
buttons to choose "YES" or "NO".
Press and release the right arrow button until "SP-31 2-STAGE
WASH ENABLED?" flashes in the left display. Press the up and down
arrow buttons to choose "YES" or "NO".